Ln-vitro testing of a new superelastic sternum closure component

  • École de technologie supérieure
  • University of Montreal

Résultats de recherche: Chapitre dans un livre, rapport, actes de conférence › Participation à un ouvrage collectif lié à un colloque ou une conférence › Revue par des pairs

1 Citation (Scopus)

Résumé

Bone binding using cable or wire-like components made of stainless steel or Co-Cr alloys are subject to fixation loosening, resulting in fracture dehiscence. A tubular braided structure made of superelastic Ti-Ni alloy, which tends towards a flat form when bent around the bone, can solve this problem. The superelastic tubular component maintains positive pressure on the closure site throughout the healing process, even after an abrupt relative movement of the connected bones, thus increasing the overall stability of the fixation. Furthermore, the new device reduces the interface pressure between the bone and the binding component by increasing the contact area. To install the device, a metallic sleeve is crimped, and retains both ends of the cable with a specially designed installation tool. The new bone binding component is also fatigue-resistant. As an example, a binding component made of 24 x 00.1 mm Ti-Ni filaments can sustain about 1000 cycles of strain-controlled fatigue testing between 4 and 8% of relative elongation. In-vitro comparative testing of the new binding component and conventional wire suture are performed on a customary testing bench, where sutures are installed directly by a surgeon. The bench can apply complex planar loading, imitating real post-operative conditions of the closed sternum. The results of the comparative testing show that the new system results in a significant gain in the residual compressive force between sternum halves following either a disruption event (coughing), or a long-term service (deep breathing). Finally, the metallic sleeve is found to be capable of sustaining one and a half times the maximum theoretical force applied on a sternum site during a coughing fit.

Langue originaleAnglais
titreSMST-2007 - Proceedings of the International Conference on Shape Memory and Superelastic Technologies
EditeurASM International
Pages497-506
Nombre de pages10
ISBN (imprimé)9780871707222
ÉtatPublié - 2008
EvénementInternational Conference on Shape Memory and Superelastic Technologies, SMST-2007 - Tsukuba, Japon
Durée: 2 déc. 2007 → 5 déc. 2007

Série de publications

NomSMST-2007 - Proceedings of the International Conference on Shape Memory and Superelastic Technologies

Conférence

ConférenceInternational Conference on Shape Memory and Superelastic Technologies, SMST-2007
Pays/TerritoireJapon
La villeTsukuba
Période2/12/07 → 5/12/07

Classification disciplinaire ASJC Scopus

  • Mécanique des matériaux

Empreinte digitale

Voici les principaux termes ou expressions associés à « Ln-vitro testing of a new superelastic sternum closure component ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource