Passer à la navigation principale Passer à la recherche Passer au contenu principal

Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification

  • K.N. Toosi University of Technology
  • École de technologie supérieure
  • University of Montreal

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

3 Citations (Scopus)

Résumé

Objective: Our study aims to advance noninvasive blood pressure (BP) monitoring through the introduction of innovative beat-to-beat oscillometric BP estimation methods. We aim to overcome current device limitations by delivering continuous and accurate BP estimates, utilizing physiologically based mathematical models. Methods: We developed novel beat-to-beat oscillometric BP estimation methods based on physiologically grounded mathematical models of intra-arterial BP and the arterial system effect. Our approach includes a recursive Bayesian method for parameter estimation and a new system identification technique to refine initial parameter estimates. We tested our methods through simulations and real-world experiments involving 10 individuals. Results: Mean errors for systolic and diastolic BP were as low as -1.26 mmHg and 2.03 mmHg, respectively, with standard deviations of errors at 5.95 mmHg and 4.16 mmHg. Furthermore, our methods enabled the estimation of additional cardiovascular parameters such as heart rate, respiration rate, and mean arterial pressure. Conclusion: Our novel beat-to-beat oscillometric BP estimation methods offer a significant advancement in noninvasive BP monitoring technology, addressing the limitations of current devices by providing continuous beat-to-beat BP estimates. Significance: Our approach represents a promising direction for improving the reliability and comprehensiveness of cardiovascular parameter estimation in noninvasive BP monitoring devices, facilitating more effective patient care and monitoring.

Langue originaleAnglais
Pages (de - à)619-629
Nombre de pages11
RevueIEEE Transactions on Biomedical Engineering
Volume72
Numéro de publication2
Les DOIs
ÉtatPublié - 2025

Classification disciplinaire ASJC Scopus

  • Ingénierie biomédicale

Empreinte digitale

Voici les principaux termes ou expressions associés à « Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource