Passer à la navigation principale Passer à la recherche Passer au contenu principal

Improving greater trochanteric reattachment with a novel cable plate system

  • École de technologie supérieure
  • Research Center - Hôpital du Sacré-Coeur de Montréal
  • University of Alberta

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

9 Citations (Scopus)

Résumé

Cable-grip systems are commonly used for greater trochanteric reattachment because they have provided the best fixation performance to date, even though they have a rather high complication rate. A novel reattachment system is proposed with the aim of improving fixation stability. It consists of a Y-shaped fixation plate combined with locking screws and superelastic cables to reduce cable loosening and limit greater trochanter movement.The novel system is compared with a commercially available reattachment system in terms of greater trochanter movement and cable tensions under different greater trochanteric abductor application angles.A factorial design of experiments was used including four independent variables: plate system, cable type, abductor application angle, and femur model. The test procedure included 50 cycles of simultaneous application of an abductor force on the greater trochanter and a hip force on the femoral head.The novel plate reduces the movements of a greater trochanter fragment within a single loading cycle up to 26%. Permanent degradation of the fixation (accumulated movement based on 50-cycle testing) is reduced up to 46%. The use of superelastic cables reduces tension loosening up to 24%. However this last improvement did not result in a significant reduction of the grater trochanter movement.The novel plate and cables present advantages over the commercially available greater trochanter reattachment system. The plate reduces movements generated by the hip abductor. The superelastic cables reduce cable loosening during cycling. Both of these positive effects could decrease the risks related to grater trochanter non-union.

Langue originaleAnglais
Pages (de - à)383-391
Nombre de pages9
RevueMedical Engineering and Physics
Volume35
Numéro de publication3
Les DOIs
ÉtatPublié - 2013

Classification disciplinaire ASJC Scopus

  • Biophysique
  • Ingénierie biomédicale

Empreinte digitale

Voici les principaux termes ou expressions associés à « Improving greater trochanteric reattachment with a novel cable plate system ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource